{"id":533,"date":"2011-06-07T15:44:04","date_gmt":"2011-06-07T15:44:04","guid":{"rendered":"http:\/\/wwelectronics.se\/?page_id=533"},"modified":"2024-05-02T08:25:19","modified_gmt":"2024-05-02T08:25:19","slug":"news-hfr100-programs","status":"publish","type":"page","link":"https:\/\/wwelectronics.se\/?page_id=533","title":{"rendered":"News HFR100 Programs"},"content":{"rendered":"<p><span style=\"color: #000000;\">Below are the latest new program features listed. Depending of your current program version, some of these may already be included in your installation. Specific news regard your\u00a0application is listed in the\u00a0user page.\u00a0If any questions, please <a style=\"color: #000000;\" title=\"Kontakter\" href=\"http:\/\/wwelectronics.se\/?page_id=60\">contact us<\/a>.<\/span><\/p>\n<p><span style=\"color: #000000;\">\u2022\u00a0<strong>2024-03-15; <\/strong>New updates from 2022-08-14<\/span><br \/>\n<span style=\"color: #000000;\">&#8211; <b>Data base <\/b>Data base updated to ver. 11 (new indexes to improve responds).<\/span><br \/>\n<span style=\"color: #000000;\">&#8211; <b>Register\u00a0 \u00a0 <\/b>Check of max serial number (warning) added.<\/span><br \/>\n<span style=\"color: #000000;\">&#8211; <b>Station\u00a0 \u00a0 \u00a0 <\/b>Station-ID added internally (not shown).<\/span><br \/>\n<span style=\"color: #000000;\">&#8211; <strong>STAT<\/strong>\u00a0 \u00a0 \u00a0 \u00a0 \u00a0 New statistics (selection of batches improved).<\/span><\/p>\n<p><span style=\"color: #000000;\"><strong>2022-08-04; <\/strong>Show Statistic\u2019s\u00a0 upgraded with the following<\/span><br \/>\n<span style=\"color: #000000;\">&#8211; <strong>Article<\/strong> (measure article), select \/ show new article.<\/span><br \/>\n<span style=\"color: #000000;\">&#8211; <strong>Show<\/strong> (=&gt; marked test), show \/ activate current test on the main screen.<\/span><br \/>\n<span style=\"color: #000000;\">&#8211; <strong>Show<\/strong> (select), show selctionl; All, All OK, All NG, Deactivated or *Tester .<\/span><br \/>\n<span style=\"color: #000000;\">&#8211; <strong>STAT<\/strong> (sum statistic\u2019s), new statistics added for all measurement total.<\/span><\/p>\n<p><span style=\"color: #000000;\">\u2022\u00a0<strong>2022-01-23; <\/strong>Added <strong>V-Cal <\/strong>(volt calibration) Fmax = 10V without reference ( TAD-3).<\/span><br \/>\n<span style=\"color: #000000;\">\u2022\u00a0<strong>2022-01-14; <\/strong>Changed <strong>pitch compensation<\/strong> to direct input values without reference.<\/span><\/p>\n<p><span style=\"color: #000000;\">\u2022\u00a0<strong>2021-09-29;<\/strong> Station-ID added to About Program and new SYS-version = 10.<\/span><br \/>\n<span style=\"color: #000000;\">\u2022\u00a0<strong>2021-07-13;<\/strong> High\u00a0 tensile speed added in Type Data list and shows %-value (rate).<\/span><br \/>\n<span style=\"color: #000000;\">\u2022\u00a0<strong>2021-05-07;<\/strong> MO Manufacturing order extended to 18 characters (extended version).<\/span><br \/>\n<span style=\"color: #000000;\">\u2022\u00a0<strong>2020-11-23; <\/strong>Post length added to About Program (About Program).<\/span><br \/>\n<span style=\"color: #000000;\">\u2022\u00a0<strong>2019-10-01; <\/strong>Warning max DB-size added + change label register to <strong>database<\/strong>.<\/span><\/p>\n<p><span style=\"color: #000000;\">\u2022\u00a0<strong>2020-04-29;\u00a0<\/strong>Calibration of elongation Axx updated to new &#8221;easier&#8221; method.<\/span><br \/>\n<span style=\"color: #000000;\">&#8211; Previous calibration dialog has been removed and replaced with a question dialog.<\/span><br \/>\n<span style=\"color: #000000;\">&#8211; Previous ACR Register is removed and replaced with a common GCR Register.<\/span><br \/>\n<span style=\"color: #000000;\">&#8211; Previous search keys; Rp, Rm, Lu are replaced by Gs , So, Rp and Lc<\/span><br \/>\n<span style=\"color: #000000;\">&#8211; Grouping for Lo (nominal measure length) plus type R, F, P or T included.<\/span><\/p>\n<p><span style=\"color: #000000;\">\u2022\u00a0<strong>2019-09-11;<\/strong><\/span><br \/>\n<span style=\"color: #000000;\">&#8211; <strong>A\/D Input<\/strong> accuracy (length and force) improved to \u00b1\u00bd bit (previous 1 bit).<\/span><br \/>\n<span style=\"color: #000000;\">&#8211; Input of <strong>max<\/strong>&#8211; <strong>min<\/strong> <strong>diameter<\/strong> add to start dialog.<\/span><br \/>\n<span style=\"color: #000000;\">&#8211; <strong>Database<\/strong> upgraded to Ver 6.68 2019-06-09 [DB: HFR100,09W].<\/span><br \/>\n<span style=\"color: #000000;\">&#8211; Calibrating of <strong>conical jaws<\/strong> are add to the calibrating dialogue. (by Calibrate X0).<\/span><br \/>\n<span style=\"color: #000000;\">&#8211; Label <strong>Roundness<\/strong> is changed to <strong>Ovality<\/strong>.<\/span><br \/>\n<span style=\"color: #000000;\">&#8211; Adjusted corrected warning<strong> tensile speed<\/strong> = SIS-norm (method a = 2, 4).<\/span><br \/>\n<span style=\"color: #000000;\">&#8211; Adjusted <strong>filter<\/strong>\/showing tensile speed = 9 step (mean value).<\/span><br \/>\n<span style=\"color: #000000;\">&#8211; Option <strong>Run 5 x nom tensile speed<\/strong> (production) is add to Run setup.<\/span><br \/>\n<span style=\"color: #000000;\">&#8211; Option <strong>Show Ag\/Agt elongation<\/strong>\u00a0is add to Run setup (Lab version).<\/span><br \/>\n<span style=\"color: #000000;\">&#8211; Refined calculation of <strong>Rp0.2<\/strong> with 2:nd degree polynomial.<\/span><br \/>\n<span style=\"color: #000000;\">&#8211; DA-1 = <strong>Analogue output<\/strong> 0 \u2013 10V is add for \u00a0control\/display of \u00a0tensile speed.<\/span><\/p>\n<p><span style=\"color: #000000;\">\u2022 <strong>2019-09-06;<\/strong>\u00a0 Serial.no XXXX changed too <strong>Raaa-XXXX<\/strong> as internal serial number.<\/span><br \/>\n<span style=\"color: #000000;\">\u2022 <strong>2019-02-28;<\/strong>\u00a0 Informing max <strong>progress<\/strong> time added to all support functions.<\/span><\/p>\n<p><span style=\"color: #000000;\">\u2022\u00a0<strong>2018-12-08;<\/strong><\/span><br \/>\n<span style=\"color: #000000;\">&#8211; Main screen adjusted for installation on <strong>Windows 10<\/strong>.<\/span><br \/>\n<span style=\"color: #000000;\">&#8211; <strong>Logotype<\/strong> and supplier (support) changed to DANOX AB.<\/span><br \/>\n<span style=\"color: #000000;\">&#8211; <strong>Reference Batch<\/strong> for current article- and test number added to the start dialogue.<\/span><br \/>\n<span style=\"color: #000000;\">&#8211; A new extended <strong>version HFR100B<\/strong> (Batch = Order) is included for custom adaptation.<\/span><\/p>\n<p><span style=\"color: #000000;\">\u2022\u00a0<strong>2018-11-07; Clear All Empty Batches<\/strong> added to the File menu.<\/span><\/p>\n<p><span style=\"color: #000000;\">\u2022 <strong>2016-06-23;<\/strong>\u00a0Input of manual elongation in mm (or inch) <strong>length<\/strong> adjusted for more secure update of the elongation correction. Previous\u00a0\u00a0ENTER key demand removed.<\/span><\/p>\n<p><span style=\"color: #000000;\"><strong>2016-05-02;<\/strong>\u00a0Calculation of\u00a0 <strong>Yield point<\/strong> Rp0.2 is improved by a new &#8221;fine tuning&#8221; correction of the E-line (Young modulus).<\/span><\/p>\n<p><span style=\"color: #000000;\">\u2022 <strong>2016-04-21;<\/strong>\u00a0Individual <strong>password<\/strong> protection is\u00a0added to the File\u00a0menu (register operations). Previous only disabling&#8217;s are removed.<\/span><\/p>\n<p><span style=\"color: #000000;\">\u2022 <strong>2016-02-11;<\/strong>\u00a0Auto logging adjusted for easier readability, and option <strong>Show only last 7 days<\/strong> is added to log Book.<\/span><\/p>\n<p><span style=\"color: #000000;\">\u2022 <strong>2016-01-11;<\/strong> Edit operation and also <strong>auto selection \u00a0<\/strong>of force scales adjusted for\u00a0Machine select (and for Start dialogue).<\/span><\/p>\n<p><span style=\"color: #000000;\">\u2022 <strong>2015-12-05;<\/strong>\u00a0New enhanced <strong>calibration filter<\/strong> added to Calibration, also common for both force- and length input\/display.<\/span><\/p>\n<p><span style=\"color: #000000;\">\u2022 <strong>2015-11-20;<\/strong>\u00a0ADC input <strong>sample time <\/strong>changed to 2 mS (higher accuracy).<\/span><\/p>\n<p><span style=\"color: #000000;\">\u2022 <strong>2015-11-11;<\/strong>\u00a0\u00a0<strong>Admin station<\/strong> add as standard to Register setup.\u00a0And previous register settings; <strong>Disable registration\u00a0<\/strong>and <strong>Disable measure system\u00a0<\/strong>are\u00a0removed.<\/span><\/p>\n<p><span style=\"color: #000000;\">\u2022 <strong>2015-11-08;<\/strong> \u00a0<strong>Mouse wheel<\/strong> added for easier scrolling of\u00a0all lists.<\/span><\/p>\n<p><span style=\"color: #000000;\">\u2022 <strong>2015-03-26; The following upgrades are\u00a0 implemented<\/strong>:<\/span><br \/>\n<span style=\"color: #000000;\">&#8211; Selectable <strong>batch labels<\/strong> add in run setup. <strong>Note:<\/strong> Batch = Charge.No is only valid (Lab).<\/span><br \/>\n<span style=\"color: #000000;\">&#8211; <strong>Link<\/strong> of current batch- and test numbers add to standard out print (registering data).<\/span><br \/>\n<span style=\"color: #000000;\">&#8211; Finish Batch replaced with <strong>End <\/strong>incl. saving of\u00a0current batch add to dialog Operator.<\/span><\/p>\n<p><span style=\"color: #000000;\">\u2022 <strong>2015-02-12; The following upgrades are\u00a0 implemented:<br \/>\n<\/strong>&#8211; Database upgrade to Ver 6.68 2015-02-12 [<strong>DB: HFR100,09V<\/strong>].<\/span><br \/>\n<span style=\"color: #000000;\">&#8211; Percentage <strong>unit<\/strong> for options\u00a0 Rp\/Rm and Rm\/Rp removed. Only decimal value is shown.<\/span><br \/>\n<span style=\"color: #000000;\">&#8211; A new gauge <strong>Agt<\/strong> is added as selectable replacement of Axx in measure article (Lab).<\/span><br \/>\n<span style=\"color: #000000;\">&#8211; A new tab <strong>Em<\/strong> for nominal E-module is added in measure article, incl correction of Ko.<\/span><br \/>\n<span style=\"color: #000000;\">&#8211; Calculation of machine\u00a0 constant <strong>Ko<\/strong> added including display in machine status.<\/span><br \/>\n<span style=\"color: #000000;\">&#8211; Display of <strong>wF<\/strong> and <strong>wX \u00a0<\/strong>on machine status is replaced by one line only as R\/e.<\/span><br \/>\n<span style=\"color: #000000;\">&#8211; New run option <strong>Print out R\/e-curve as default (not NRP) is <\/strong>added.<\/span><\/p>\n<p><span style=\"color: #000000;\">\u2022\u00a0<strong>2014-08-30; <\/strong><strong>Register new MO at start<\/strong> removed from Run option \u00a0(HFR100E).<\/span><\/p>\n<p><span style=\"color: #000000;\">\u2022\u00a0<strong>2014-05-01; The following upgrades are\u00a0 implemented:<br \/>\n<\/strong>&#8211;\u00a0Display of <strong>R\/e-curve<\/strong> (stress\/strain) is added.<\/span><br \/>\n<span style=\"color: #000000;\">&#8211;\u00a0Calculation of <strong>E-modulus\u00a0<\/strong> (Lab)\u00a0 adjusted for Lo.<\/span><br \/>\n<span style=\"color: #000000;\">&#8211;\u00a0Selectable display of tensile in\u00a0<strong>MPa<\/strong> unit added in run setup.<\/span><\/p>\n<p><span style=\"color: #000000;\">\u2022\u00a0<strong>2013-08-10;\u00a0<\/strong><strong>Rm\/Rp-Ratio<\/strong> is added as new option gauge and\u00a0previous label <strong>K <\/strong>(ratio) is replaced with the same symbol (also for Rp\/Rm ratio).<\/span><\/p>\n<p><span style=\"color: #000000;\">\u2022\u00a0<strong>2013-04-15; Automatic selection of machine\/force scale <\/strong>for new article is added to dialog Define Measure article, and <strong>warnings<\/strong> for\u00a0 force scale (to low or high) are adjusted to 5% resp. 95% in the start dialog.<\/span><\/p>\n<p><span style=\"color: #000000;\">\u2022\u00a0<strong>2013-03-25;\u00a0New correction of elongation A<\/strong> is added , based on Bertella-Oliver equation (SIS 2566-1) including a\u00a0special new calibrating dialog. The correction is further expressed directly in <strong>% unit<\/strong> of the elongation.<\/span><\/p>\n<p><span style=\"color: #000000;\">\u2022\u00a0<strong>2013-03-23;\u00a0Pitch compensation <\/strong>added for force calibration.<\/span><\/p>\n<p><span style=\"color: #000000;\">\u2022\u00a0<strong>2013-03-04;\u00a0Max tensile speed <\/strong>for NRP and springs are adapted for automatic select in run setup (not standard SIS method regulated).<\/span><\/p>\n<p><span style=\"color: #000000;\">\u2022\u00a0<strong>2013-03-03;\u00a0Correction A5 <\/strong>adjusted to; dX = F(machine, method, Lo, Fm, Rm and dLu) where dX corresponds to a constant error in dLn. And a special new correction linked to current article is added as default.<\/span><\/p>\n<p><span style=\"color: #000000;\">\u2022\u00a0<strong>2012-11-03<br \/>\n<\/strong>&#8211; New <strong>measure list<\/strong> with line specific viewing.<\/span><br \/>\n<span style=\"color: #000000;\">&#8211; Secondary gauges <strong>ReH<\/strong>, <strong>ReL<\/strong> and <strong>E-module<\/strong> added to measure list.<\/span><br \/>\n<span style=\"color: #000000;\">&#8211; Gauge <strong>RpX<\/strong> and <strong>ReH<\/strong> exchangeable as primary gauge\/viewing in measure article.<\/span><br \/>\n<span style=\"color: #000000;\">&#8211; <strong>Imperial units<\/strong> (in, lbf och ksi etc.) added to Register setup.<\/span><br \/>\n<span style=\"color: #000000;\">&#8211; <strong>Out prints<\/strong> adjusted. Symbols for dimensions added.<\/span><br \/>\n<span style=\"color: #000000;\">&#8211; <strong>Correction of A5<\/strong> adjusted to; machine(Kn) = function of (So, Rm, dLu och dLn).<\/span><br \/>\n<span style=\"color: #000000;\">&#8211; New method <strong>tube test <\/strong>added to Define Define measure article.<\/span><br \/>\n<span style=\"color: #000000;\">&#8211; Automatic calculation\/warning of <strong>max tensile speed<\/strong> added to Define measure article.<\/span><br \/>\n<span style=\"color: #000000;\">&#8211; A\/D-card (driver) adjusted for <strong>32\/64 bit version<\/strong> BioDaq (wwCOMBDaq.Dll).<\/span><\/p>\n<p><span style=\"color: #000000;\">\u2022 <strong>2012-01-15; New basic version 6.68<\/strong>. A new basic version of HFR100 is released. The new version has an extended screen size (1024 x 729),\u00a0a new measure list, graph\u00a0and also better adaptation for Windows 7, 8 (32\/64 bit). <strong>Note! <\/strong>Present version is functionally exact equivalent to version 6.67, but will be extended with new functions further on. For ex:<\/span><br \/>\n<span style=\"color: #000000;\">&#8211; Test modes for tubes, veiwing tensile graph in stress\/strain mode (lab), and moore..<\/span><\/p>\n<p><span style=\"color: #000000;\">\u2022 <strong>2011-06-01; Connection to Web User page<\/strong>. A new direct web access from the Help-menu,\u00a0 intended for\u00a0verifying, backup and feed back of your current installation.<\/span><\/p>\n<p><span style=\"color: #000000;\">\u2022 <strong>2011-05-17; <\/strong><strong>Clear active article<\/strong>. A new article function in File-menu for backup and clearing the article. It also resets the internal serial number to zero. Note! This is the manual\u00a0 operation for the\u00a0automatic clear operation when\u00a0max serial number is reached.<\/span><\/p>\n<p><span style=\"color: #000000;\">\u2022 <strong>2011-04-22; <\/strong><strong>Adaptation to Windows 7<\/strong>. In order to run and reinstall the program correctly for Windows 7. Note! Also an earlier special adaptation for XP was made.<\/span><\/p>\n<p><span style=\"color: #000000;\">\u2022 <strong>2010-12-12; <\/strong><strong>Automatic calculation of A5<\/strong>. A new developed method for <span style=\"text-decoration: underline;\">estimating the elongation<\/span> directly from the tensile curve. This new method is based on analyzing the plastic and fracture part of the curve, and then calculate the nominal elongation due to the\u00a0specified test length. The elongation can also be manually input as standard measure.<\/span><br \/>\n<span style=\"color: #000000;\">Also previous tensile labels and notations has been adjusted in order to correspond to the new standard: SS-EN ISO 6892-1:2009.<\/span><br \/>\n<span style=\"color: #000000;\"><em>Update description: <\/em><a style=\"color: #000000;\" href=\"http:\/\/wwelectronics.se\/Support\/HFR100\/u_HFR100E-2010-11-12_se.pdf\" target=\"_blank\" rel=\"noopener noreferrer\">u_HFR100E-2010-11-12_se.pdf <\/a>(extended)<\/span><br \/>\n<span style=\"color: #000000;\"><em>Update description: <\/em><a style=\"color: #000000;\" href=\"http:\/\/wwelectronics.se\/Support\/HFR100\/u_HFR100i_2010-11-12_se.pdf\" target=\"_blank\" rel=\"noopener noreferrer\">u_HFR100i-2010-11-12_se.pdf <\/a> (standard\/lab)<\/span><\/p>\n<p><span style=\"color: #000000;\">\u2022 <strong>2010-10-29; Z<\/strong><strong><strong>ero force adjustment<\/strong><\/strong>. A new separate manual zero operation for compensation of drifts\/offset in the force signal (calibration dialoge).<\/span><\/p>\n<p><span style=\"color: #000000;\">\u2022 <strong>2010-08-19; <\/strong><strong><strong>Filter and noise reduction<\/strong><\/strong>. A new input filter for detection and eliminating\u00a0of extremely highly disturbance on the input force, including a second filter for smoothing the tensile curve in order\u00a0to <span style=\"text-decoration: underline;\">improve the accuracy<\/span> for the yield point Rm. An improved curve analyzing has also been implemented for eliminating\u00a0and detect glitches and gaps on the input curve, including compensation for machine oscillations after fracture.<\/span><\/p>\n<p><span style=\"color: #000000;\">\u2022 <strong>2010-02-26; Automatic input rate control<\/strong>. A new analogue input function and basic filter\u00a0making a steady input rate = 100 Hz (and automatic filter\/frequency control).<\/span><\/p>\n","protected":false},"excerpt":{"rendered":"<p>Below are the latest new program features listed. Depending of your current program version, some of these may already be included in your installation. Specific news regard your\u00a0application is listed in the\u00a0user page.\u00a0If any questions, please contact us. \u2022\u00a02024-03-15; New &hellip; <a href=\"https:\/\/wwelectronics.se\/?page_id=533\">Forts\u00e4tt l\u00e4sa <span class=\"meta-nav\">&rarr;<\/span><\/a><\/p>\n","protected":false},"author":1,"featured_media":0,"parent":322,"menu_order":0,"comment_status":"closed","ping_status":"open","template":"","meta":[],"_links":{"self":[{"href":"https:\/\/wwelectronics.se\/index.php?rest_route=\/wp\/v2\/pages\/533"}],"collection":[{"href":"https:\/\/wwelectronics.se\/index.php?rest_route=\/wp\/v2\/pages"}],"about":[{"href":"https:\/\/wwelectronics.se\/index.php?rest_route=\/wp\/v2\/types\/page"}],"author":[{"embeddable":true,"href":"https:\/\/wwelectronics.se\/index.php?rest_route=\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"https:\/\/wwelectronics.se\/index.php?rest_route=%2Fwp%2Fv2%2Fcomments&post=533"}],"version-history":[{"count":74,"href":"https:\/\/wwelectronics.se\/index.php?rest_route=\/wp\/v2\/pages\/533\/revisions"}],"predecessor-version":[{"id":1794,"href":"https:\/\/wwelectronics.se\/index.php?rest_route=\/wp\/v2\/pages\/533\/revisions\/1794"}],"up":[{"embeddable":true,"href":"https:\/\/wwelectronics.se\/index.php?rest_route=\/wp\/v2\/pages\/322"}],"wp:attachment":[{"href":"https:\/\/wwelectronics.se\/index.php?rest_route=%2Fwp%2Fv2%2Fmedia&parent=533"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}